Test Code LAB1486 Immunoglobulins (IgG, IgA, and IgM), Serum
Additional Codes
Mayo Test ID |
---|
IMMG |
Reporting Name
Immunoglobulins IgG,A,M, SUseful For
Detecting or monitoring of monoclonal gammopathies and immune deficiencies
Performing Laboratory
Mayo Clinic Laboratories in RochesterSpecimen Type
SerumSpecimen Required
Collection Container/Tube:
Preferred: Serum gel
Acceptable: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL
Collection Instructions: Centrifuge and aliquot serum into a plastic vial.
Specimen Minimum Volume
0.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Refrigerated (preferred) | 28 days | |
Frozen | 28 days | ||
Ambient | 14 days |
Reference Values
IgG
0-<5 months: 100-334 mg/dL
5-<9 months: 164-588 mg/dL
9-<15 months: 246-904 mg/dL
15-<24 months: 313-1,170 mg/dL
2-<4 years: 295-1,156 mg/dL
4-<7 years: 386-1,470 mg/dL
7-<10 years: 462-1,682 mg/dL
10-<13 years: 503-1,719 mg/dL
13-<16 years: 509-1,580 mg/dL
16-<18 years: 487-1,327 mg/dL
≥18 years: 767-1,590 mg/dL
IgA
0-<5 months: 7-37 mg/dL
5-<9 months: 16-50 mg/dL
9-<15 months: 27-66 mg/dL
15-<24 months: 36-79 mg/dL
2-<4 years: 27-246 mg/dL
4-<7 years: 29-256 mg/dL
7-<10 years: 34-274 mg/dL
10-<13 years: 42-295 mg/dL
13-<16 years: 52-319 mg/dL
16-<18 years: 60-337 mg/dL
≥18 years: 61-356 mg/dL
IgM
0-<5 months: 26-122 mg/dL
5-<9 months: 32-132 mg/dL
9-<15 months: 40-143 mg/dL
15-<24 months: 46-152 mg/dL
2-<4 years: 37-184 mg/dL
4-<7 years: 37-224 mg/dL
7-<10 years: 38-251 mg/dL
10-<13 years: 41-255 mg/dL
13-<16 years: 45-244 mg/dL
16-<18 years: 49-201 mg/dL
≥18 years: 37-286 mg/dL
Day(s) Performed
Monday through Friday
Test Classification
This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.CPT Code Information
82784 x 3
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
IMMG | Immunoglobulins IgG,A,M, S | 34550-4 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
IGA | Immunoglobulin A (IgA), S | 2458-8 |
IGM | Immunoglobulin M (IgM), S | 2472-9 |
IGG | Immunoglobulin G (IgG), S | 2465-3 |
Interpretation
Increased serum immunoglobulin concentrations occur due to polyclonal or oligoclonal immunoglobulin proliferation in hepatic disease (eg, hepatitis, liver cirrhosis), connective tissue diseases, acute and chronic infections, as well as in the cord blood of neonates with intrauterine and perinatal infections.
Elevations of IgG, IgA, or IgM may occur in monoclonal gammopathies such as multiple myeloma (IgG, IgA), macroglobulinemia (IgM), primary systemic amyloidosis, monoclonal gammopathy of undetermined significance, and related disorders.
Decreased levels are found in patients with primary or secondary immune deficiencies.
Report Available
1 to 3 daysSpecimen Retention Time
14 daysReject Due To
Gross hemolysis | OK |
Gross lipemia | Reject |
Gross icterus | OK |
Method Name
Nephelometry
Forms
If not ordering electronically, complete, print, and send a Gastroenterology and Hepatology Test Request (T728) with the specimen.