Test Code LAB1276 Iodine, Serum
Additional Codes
Mayo Test ID |
---|
IOD |
Performing Laboratory
Mayo Clinic Laboratories in RochesterUseful For
Determining iodine overload using serum specimens
Monitoring iodine levels in individuals taking iodine-containing drugs
Special Instructions
Method Name
Inductively Coupled Plasma Mass Spectrometry (ICP-MS)
Reporting Name
Iodine, SSpecimen Type
SerumSpecimen Required
Patient Preparation:
1. Disinfectants (such as Betadine) that contain iodine should not be used during venipuncture.
2. High concentrations of gadolinium and iodine are known to interfere with most metal tests. If either gadolinium- or iodine-containing contrast media has been administered, a specimen should not be collected for 96 hours.
Supplies:
-Metal Free B-D Tube (No Additive), 6 mL (T184)
-Metal Free Specimen Vial (T173)
Collection Container/Tube: Plain, royal blue-top Vacutainer plastic trace element blood collection tube
Submission Container/Tube: 7-mL Mayo metal-free, screw-capped, polypropylene vial
Specimen Volume: 1 mL
Collection Instructions:
1. Allow specimen to clot for 30 minutes; then centrifuge the specimen to separate serum from the cellular fraction.
2. Remove the stopper. Carefully pour specimen into Mayo metal-free, polypropylene vial, avoiding transfer of the cellular components of blood. Do not insert a pipet into the serum to accomplish transfer, and do not ream the specimen with a wooden stick to assist with serum transfer.
3. See Trace Metals Analysis Specimen Collection and Transport for complete instructions.
Specimen Minimum Volume
0.3 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Refrigerated (preferred) | 21 days | |
Ambient | 21 days | ||
Frozen | 21 days |
Reject Due To
Gross hemolysis | OK |
Gross lipemia | OK |
Gross icterus | OK |
Reference Values
40-92 ng/mL
Interpretation
Values between 80 ng/mL and 250 ng/mL have been reported to indicate hyperthyroidism.
Values above 250 ng/mL may indicate iodine overload.
Day(s) Performed
Tuesday, Friday
Report Available
1 to 4 daysSpecimen Retention Time
14 daysTest Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
83789
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
IOD | Iodine, S | 2494-3 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
81574 | Iodine, S | 2494-3 |