Test Code LAB02936701 Blood Gases, Venous Cord Blood
Methodology
Electrode Methodology
Includes pH, pCO2, pO2, bicarbonate (HCO3), base excess, and % O2 saturation.
Performing Laboratory
CentraCare Laboratory Services
Specimen Requirements
Specimen Type: Venous cord blood
Container/Tube: Heparinized blood gas syringe
Specimen Volume: 0.5 mL
Minimum Volume: 0.25 mL
Collection Instructions:
1. Immediately mix and send in syringe.
2. Avoid exposure of specimen to atmosphere.
3. If clots are present, testing will be canceled and nursing staff will be notified.
Specimen Transport Temperature
Ambient
Reference Values
pH: 7.30-7.40 units
Critical values (automatic call-back): ≤7.25 units or ≥7.60 units
pCO2: 33.9-48.3 mm Hg
Critical values (automatic call-back): ≤20 mm Hg or ≥70 mm Hg
pO2: 22.8-34.6 mm Hg
Critical value (automatic call-back): <30 or >40 mm Hg
HCO3: 23-28 mmol/L
Critical values (automatic call-back): ≤14 mmol/L or ≥40 mmol/L
Base excess: -2.0 to 3.0 mmol/L
% O2 saturation: 60-80%
Day(s) Test Set Up
Monday through Sunday
Test Classification and CPT Coding
82803