Test Code LAB0232058 Erythropoietin, Serum
Additional Codes
Mayo Test ID |
---|
EPO |
Performing Laboratory
Mayo Clinic Laboratories in RochesterUseful For
An aid in distinguishing between primary and secondary polycythemia
Differentiating between appropriate secondary polycythemia (eg, high-altitude living, pulmonary disease, tobacco use) and inappropriate secondary polycythemia (eg, tumors)
Identifying candidates for erythropoietin (EPO) replacement therapy (eg, those with chronic renal failure)
Evaluating patients undergoing EPO replacement therapy who demonstrate an inadequate hematopoietic response
Testing Algorithm
The following algorithms are available in Special Instructions:
-Erythrocytosis Evaluation Testing Algorithm
-Myeloproliferative Neoplasm: A Diagnostic Approach to Bone Marrow Evaluation
-Myeloproliferative Neoplasm: A Diagnostic Approach to Peripheral Blood Evaluation
Special Instructions
Method Name
Immunoenzymatic Assay
Reporting Name
Erythropoietin (EPO), SSpecimen Type
SerumSpecimen Required
Collection Container/Tube:
Preferred: Serum gel
Acceptable: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 0.6 mL
Collection Instructions:
1. Morning collection, 7:30 a.m.-12 p.m. is preferred due to diurnal variation. For more information see Cautions.
2. Centrifuge and aliquot serum into a plastic vial.
Specimen Minimum Volume
0.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Refrigerated (preferred) | 14 days | |
Frozen | 14 days | ||
Ambient | 7 days |
Reject Due To
Gross hemolysis | Reject |
Gross lipemia | OK |
Gross Icterus | OK |
Reference Values
2.6-18.5 mIU/mL
Interpretation
In the appropriate clinical setting (eg, confirmed elevation of hemoglobin >18.5 g/dL, persistent leukocytosis, persistent thrombocytosis, unusual thrombosis, splenomegaly, and erythromelalgia), polycythemia vera is unlikely when erythropoietin (EPO) levels are elevated but is likely when EPO levels are suppressed.
EPO levels are also increased in patients with anemia of bone marrow failure, iron deficiency, or thalassemia.
Patients, who have either a poor or no erythropoietic response to EPO therapy, but high-normal or high EPO levels, may have additional, unrecognized causes for their anemia. If no contributing factors can be identified after adequate further study, the possibility that the patient may have developed EPO-antibodies should be considered. This can be a serious clinical situation that can result in red cell aplasia and should prompt expeditious referral to hematologists or immunologists skilled in diagnosing and treating this disorder.
Day(s) Performed
Monday through Friday
Report Available
1 to 3 daysSpecimen Retention Time
14 daysTest Classification
This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.CPT Code Information
82668
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
EPO | Erythropoietin (EPO), S | 15061-5 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
EPO | Erythropoietin (EPO), S | 15061-5 |
Forms
If not ordering electronically, complete, print, and send 1 of the following forms with the specimen:
-General Request (T239)
-Benign Hematology Test Request (T755)