Test Code LAB0208801 Leukocyte Count (WBC), Hemoglobin and Platelet Count, (H3), Blood
Methodology
Coulter VCS Technology
Includes WBC, hemoglobin, and platelets.
Performing Laboratory
CentraCare Laboratory Services
Specimen Requirements
Specimen Type: Whole blood
Container/Tube: Lavender top (EDTA)
Specimen Volume:4 mL
Microtainer: 0.55 ml
Specimen Transport Temperature
Refrigerated
Reference Values
WBC
Males
1-30 days: 9.6-24.8 x 103/uL
1-2 months: 5.0-20.0 x 103/uL
2-11 months: 5.0-15.0 x 103/uL
1-2 years: 6.0-11.0 x 103/uL
3-4 years: 5.0-12.0 x 103/uL
5-7 years: 4.0-12.0 x 103/uL
8-12 years: 3.4-10.8 x 103/uL
>12 years: 3.9-11.9 x 103/uL
Critical values (automatic call-back): ≤1.5 x
103/uL or >30.0 x 103/uL
Females
1-30 days: 9.6-24.8 x 103/uL
1-2 months: 5.0-20.0 x 103/uL
2-11 months: 5.0-15.0 x 103/uL
1-2 years: 6.0-11.0 x 103/uL
3-4 years: 5.0-12.0 x 103/uL
5-7 years: 4.0-12.0 x 103/uL
8-12 years: 3.4-10.8 x 103/uL
>12 years: 3.7-12.1 x 103/uL
Critical values (automatic call-back): ≤1.5 x
103/uL or >30.0 x 103/uL
HEMOGLOBIN
Males
1-30 days: 13.9-20.3 g/dL
1-2 months: 10.0-20.0 g/dL
3-11 months: 10.0-14.0 g/dL
1-2 years: 10.5-13.5 g/dL
3-4 years: 11.0-14.0 g/dL
5-7 years: 11.0-14.5 g/dL
8-12 years: 12.0-14.5 g/dL
>12 years: 13.1-17.1 g/dL
Critical value (automatic call-back): <7.0 g/dL
Females
1-30 days: 13.9-20.3 g/dL
1-2 months: 10.0-20.0 g/dL
3-11 months: 10.0-14.0 g/dL
1-2 years: 10.5-13.5 g/dL
3-4 years: 11.0-14.0 g/dL
5-7 years: 11.0-14.5 g/dL
8-12 years: 12.0-14.5 g/dL
>12 years: 11.2-15.8 g/dL
Critical value (automatic call-back): <7.0 g/dL
PLATELETS
1-30 days: 174-400 x 103/uL
1 month-7 years: 150-350 x 103/uL
8-12 years: 150-450 x 103/uL
>12 years: 179-450 x 103/uL
Critical values (automatic call-back): <50 x
103/uL or >1,000 x 103/uL
Day(s) Test Set Up
Monday through Sunday
Test Classification and CPT Coding
WBC 85048
Hemoglobin 85018
Platelet Count 85049