Sign in →

Test Code LAB0205575 Lithium, Serum

Methodology

Colorimetric Reflectance Spectrophotometry (SP)

Performing Laboratory

CentraCare Laboratory Services

Specimen Requirements

Specimen Type: Serum

Container/Tube:

Preferred:  Serum gel (Gold/SST) or plain red top

Acceptable: Na Heparin Plasma (label speceimen appropriately)  NO Lithium Heparin

Specimen Volume: 1 mL

Specimen Minimum Volume:  0.25 ml

 

Collection Instructions: Draw blood just prior to next dose.

Specimen Transport Temperature

Refrigerated

Reference Values

Therapeutic concentration: 0.6-1.2 mmol/L
Toxic concentration (automatic call-back): ≥2.0 mmol/L

Day(s) Test Set Up

Monday through Sunday

Test Classification and CPT Coding

80178