Sign in →

Test Code FIL2M Interleukin 2, Serum

Performing Laboratory

ARUP Laboratories

Method Name

Quantitative Multiplex Bead Assay

Reporting Name

Interleukin 2

Specimen Type

Varies


Specimen Required


Collection Container/Tube: Serum gel or red top

Submission Container/Tube: Plastic vial

Specimen Volume: 1 mL Serum

Collection Instructions:

1. As soon as possible or within 2 hours of collection, centrifuge and aliquot 1 mL of serum into a plastic vial.

2. Send frozen.

 

Note: Separate specimens must be submitted when multiple tests are ordered.

Cytokine levels may demonstrate diurnal variation. For longitudinal comparison, it is recommended that cytokine levels be determined at the same time of day.


Specimen Minimum Volume

Serum: 0.4 mL

Specimen Stability Information

Specimen Type Temperature Time
Varies Frozen 365 days

Reject Due To

Contaminated specimens Reject
Heat-inactivated specimens Reject

Reference Values

≤2.1 pg/mL

Interpretation

Results are used to understand the pathophysiology of immune, infectious, or inflammatory disorders, or may be used for research purposes.

Day(s) Performed

Monday through Sunday

Report Available

1 to 12 days

Test Classification

This test was developed and its performance characteristics determined by ARUP Laboratories.

CPT Code Information

83520

LOINC Code Information

Test ID Test Order Name Order LOINC Value
FIL2M Interleukin 2 33939-0

 

Result ID Test Result Name Result LOINC Value
FIL2M Interleukin 2 33939-0