Test Code F100B S-100B Protein, Serum
Performing Laboratory
ARUP LaboratoriesMethod Name
Quantitative Enzyme-Linked Immunosorbent Assay
Reporting Name
S-100B Protein, SerumSpecimen Type
SerumSpecimen Required
Draw blood in a plain, red-top tube(s). Serum gel tube is acceptable. Allow specimen to clot at room temperature. Spin down and send 2 mL of serum refrigerated in a plastic vial.
Specimen Minimum Volume
0.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Refrigerated (preferred) | 7 days | |
Frozen | 90 days | ||
Ambient | 24 hours |
Reject Due To
Hemolysis: | NA |
Thawing: | Warm reject, Cold OK |
Lipemia: | NA |
Icterus: | NA |
Other: | NA |
Reference Values
Age |
Reference Interval |
19 years and older: |
0 - 96 ng/L |
3 years to 19 years: |
less than or equal to 160 ng/L |
25 months to 3 years |
less than or equal to 170 ng/L |
10 months to 25 months: |
less than or equal to 230 ng/L |
5 months to 10 months: |
less than or equal to 350 ng/mL |
0 days to 5 months: |
less than or equal to 510 ng/mL |
Day(s) Performed
Tuesday
Report Available
1 to 18 daysTest Classification
This test was developed and its performance characteristics determined by ARUP Laboratories. It has not been cleared or approved by the US Food and Drug Administration. This test was performed in a CLIA certified laboratory and is intended for clinical purposes.CPT Code Information
86316
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
F100B | S-100B Protein, Serum | 47275-3 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
Z2708 | S-100B Protein, S | 47275-3 |